4.5.7

Diagnostic Parameters

Code
No.
Name
Fault History
p500
Software Version
P501
Drive ID
P502
Internal Code
P503
DC Bus Voltage
P505
Motor Voltage
P506
Load
P507
Motor Current
P508
Torque
P509
Output Power kW
P510
Total kWh
P511
Heatsink Temp
P512
0-10 VDC Input
P520
4-20 mA Input
P521
TB-5 Feedback
P522
TB-25 Feedback
P523
Network Feedback P204
P524
Analog Output
P525
Actual Output
P527
Frequency
Network Speed
P528
Command
Terminal and
P530
Protection Status
Keypad Status
P531
Total Run Time
P540
Total Power On
P541
Time
Fault History
P550
Fault History Time
P551
Fault History
P552
Counter
EDBSV571 EN 1.0
Display Range (READ ONLY)
0
{VDC}
1500
0
{VAC}
1000
0
{%}
255
0.0
{A}
1000
0
{%}
500
0.00
{kW}
650.0
0.0
{kWh}
9999999 Alternating display: xxx-; yyyy when value exceeds 9999
0
{°C}
150
0.0
{VDC}
10.0
0.0
{mA}
20.0
P204
P205
P204
P205
P205
0
{VDC}
10.0
0
{Hz}
500.0
0
{Hz}
500.0
0
{h}
9999999 Alternating display: xxx-; yyyy when value exceeds 9999
0
{h}
9999999
1
8
0
{h}
999999
0
255
Commissioning
IMPORTANT
• Displays the last 8 faults
• Format: n.xxx where: n = 1..8,
1 is the newest fault; xxx = fault message (w/o the F.)
• Refer to section 5.3
Format: x.yz
A flashing display indicates that the Drive ID stored in
the EPM does not match the drive model it is plugged
into.
Alternating Display: xxx-; -yy
Motor load as % of drive's output current rating.
Refer to section 2.3.
Actual motor current
Torque as % of motor rated torque (vector mode only)
Heatsink temperature
Actual value of signal at TB-5 (See P162)
Actual value of signal at TB-25 (See P162)
TB-5 signal value scaled to PID feedback units (See P162)
TB-25 signal value scaled to PID feedback units (See
P162)
Network signal value scaled to PID feedback units
Refer to P150...P155
Command speed if (Auto: Network) is selected as the
speed source
Indicates terminal status using segments of the LED
display. (Refer to section 4.5.7.1)
Indicates keypad button status using segments of the
LED display. (Refer to section 4.5.7.2)
• Displays the last 8 faults
• Format: n.xxx where: n = 1..8,
1 is the newest fault; xxx = fault message (w/o the F.)
• Refer to section 5.3
Display: "n.hh-" "hhhh" "mm.ss" = fault #, hours, seconds
The "hhhh" screen is displayed after hours exceed 999.
Number of sequential occurrences of a fault.
For example: 3 external faults occur over a period of
time with no other errors occurring. Then P552 will
indicate 3, P550 will indicate the error EF and P551 will
indicate the time of the first fault occurrence.