Lenze SMV Series Operating Instructions Manual page 28

Table of Contents

Advertisement

Commissioning
Code
No.
Name
Keypad Setpoint
p176
Single Press
Increment
Display Frequency
p178
Multiplier
Run Screen Display
p179
EN
Oscillation
p180
Damping Control
Skip frequency 1
p181
Skip frequency 2
p182
Skip frequency
p184
bandwidth
Voltage Midpoint
p185
V/Hz characteristic
Frequency
(2)
p187
Midpoint V/Hz
characteristic
Motor Braking
p190
Motor Brake Level
p191
26
Possible Settings
Default
Selection
0.1
0.1
0.00
0.00
EXAMPLE
If
P178 = 29.17 and actual frequency = 60 Hz, then Drive displays 1750 (rpm)
0
0
{Parameter Number}
0
0
0.0
0.0
{Hz}
0.0
0.0
{Hz}
0.0
0.0
{Hz}
NOTE
Bandwidth (Hz) = f
(Hz) + P184 (Hz)
s
EXAMPLE: P181 = 18 Hz and P184 = 4 Hz; skip range is from 18 to 22 Hz
0
0.0
{V}
0.0
0.0
{Hz}
0 Disabled
1 Braking with BUS threshold
2 Braking always on with
deceleration
3 Braking with bus regulator
4 Special
WARNING
Flux braking can cause heat in the motor. To avoid damage to the motor, use a PTC
to protect the motor. If the flux brake is used too frequently, the drive will trip fault
"F_PF".
0
0
{%}
(flux
braking
disabled)
IMPORTANT
100.0
Used for run screen setpoint editing only.
If P176 >0.1 then scrolling of keypad setpoint
is enabled.
650.00
• Allows frequency display to be scaled
• P178 = 0.00: Scaling disabled
• P178 > 0.00: Display = Actual Frequency
X P178
599
• 0 = Normal Run Screen, this display depends
on mode of operation. Refer to section 4.2.
• Other selections choose a diagnostic
parameter to display (P501...P599).
• Parameters P560 - P564 are selectable
if the sequencer is enabled (P700 is not
0). P560-P564 are not visible until P700
is enabled.
80
0 = Damping disabled
Compensation for resonances within drive
500
• Drive will not run in the defined skip range;
used to skip over frequencies that cause
500
mechanical vibration
10.0
• P181 and P182 define the start of the
skip ranges
• P184 > 0 defines the bandwidth of both
ranges.
f
= P181 or P182
s
P165
Valid only when P300 = 0 or 2.
Use with P187 to define midpoint on V/Hz
curve.
P167
Valid only when P300 = 0 or 2.
Use with P185 to define midpoint on V/Hz
curve.
Flux brake OFF.
When drive is in deceleration and V
V
(114% of the rated V
deceleration freeze
brake will be turned ON.
As long as drive is in deceleration, the flux
brake will be ON.
When drive is in deceleration and V
(114% of the rated V
freeze
increased to reduce the bus voltage. Determined by
the value in P191, the speed increment = slip speed *
P191(%) / 37.
(Consult factory before using)
75
Active when P190 > 0 and drive is in deceleration
mode. Use to reduce deceleration time on high
inertia loads.
NOTE: Over usage of P190 can cause frequent
'overload' trips "F.PF"
Not active for P300 = 5 (Torque mode)
>
bus
), the flux
bus
> V
bus
deceleration
), the motor speed will be
bus
EDBSV571 EN 1.0