QUANTA QuantaGrid Series User Manual page 92

Versatile compact 2-socket server
Table of Contents

Advertisement

BMC
2. Select one of PEF ID list and click Modify to modify event Filter entry page. A sample
screenshot of modify Event Filter Page is in seen the screenshot below.
3. In the Event Filter Configuration section,
PEF ID displays the ID for configured PEF entry (read?]only).
In filter configuration, check the box to enable the PEF settings.
4. In the Filter Action configuration section,
Event Filter Action is a mandatory field and checked by default, which enable PEF
Alert action (read-only).
Select any one of the Power action either Power down, Power reset or Power cycle
from the drop down list
Choose any one of the configured alert policy number from the drop down list.
Note:
Alert Policy has to be configured - under Configuration -> PEF -> Alert Policy.
5. In the Sensor configuration section,
Select the s type of sensor that will trigger the event filter action.
In the sensor name field, choose the particular sensor from the sensor list.
Choose event option to be either All Events or Sensor Specific Events.
6. Click Modify to accept the modification and return to Event filter list.
7. Click Reset to reset the modification done.
8. Click on Cancel to cancel the modification and return to Event filter list.
9. In the Event filter list, to modify a configuration, select the slot to be modified and
click Modify.
10. In the Event filter list, click Delete to delete the existing filter.
Figure 3-26. Add Event Filter Entry Page