BMC
Table 9: Event Log Page
I
TEM
Event Log Category
Filter Type
BMC Timezone
Client Timezone
Clear All Event Logs
Download All Event Logs (Text
format):
Download All Event Logs (Hex
format)
Procedure:
1. From the Event Log Category drop-down menu select the event categories.
2. From the Filter Type drop down list select the sensor name filter to view the event
for the selected filter.
3. Select either BMC Timezone or Client Timezone. The list of events is listed.
4. To clear all events from the list, click the Clear All Event Logs button.
SEL Severity
The Event Log page specifies the severity of the SEL to identify the event severity code as
follows:
: Severity Information
: Severity Warning
: Severity Critical
: Severity Non-Recoverable
: Severity Unspecified
The category options: All Events, System Event Records, BIOS Gener-
ated Events, SMI Handler Events, System Management Software Events,
System Software - OEM Events, Remote Console software Events, Termi-
nal Mode Remote Console software Events.
Filtering can be done with the sensors mentioned in the list.
Note:
Once the Event Log category and Filter type are selected, the list of
events will be displayed with the Event ID, Time Stamp, Sensor Type,
Sensor Name and Description.
BMC UTC offset timestamp value of the events.
Events of client UTC offset timestamp.
Deletes all the existing records for all the sensors.
To download all existing records for all sensors. Default filename is
SEL.txt.
To download all existing records for all sensors. Default filename is
SEL_Hex.txt.
D
ESCRIPTION
FRU I
NFORMATION