Command: ipmitool raw 0x0a 0x24 0x0 0x0 0x51 0xc0 4 0x57 0x01 0x0 0xf5
Response: 55 00 „» 55 is the last record ID
Step 2: get OEM record, to use the last record ID to check if added successfully (
Please refer to IPMI 2.0 Spec. page 466/644)
Command: ipmitool raw 0x0a 0x23 0x0 0x0 0x55 0x0 0x0 0xff
Response: ff ff 55 00 51 c0 04 57 01 0 f5 „» ff ff means record ID 55 is the last record ID
Step 3: go to Web.UI to check "SDR" to be preserved
Step 4: upgrade firmware
Step 5: after Step 4, go to Step 2 and check if the OEM record is still preserved (if pre-
served then PASS else FAIL)
2. SEL
Step 1: Please use IPMI command to add an event. Ex: ipmitool event 1
Step 2: go to Event Log to check if the event added
Step 3: go to Web.UI to check "SEL" to be preserved
Step 4: upgrade firmware
Step 5: after Step 4, go to Step 2 and check if the event is still preserved (if preserved
then PASS else FAIL)
3. IPMI
Step 1: Please add a new user by Web.
Step 2: check if the user added
Step 3: go to Web.UI to check ¡§IPMI¡¨ to be preserved
Step 4: upgrade firmware
Step 5: after Step 4, go to Step 2 and check if the user is still exist (if preserved then
PASS else FAIL)
4. Network
Step 1: Please change BMC IPv4 address source to be STATIC or DHCP mode by Web.
Step 2: check if the mode changed
Step 3: go to Web.UI to check ¡§Network¡¨ to be preserved
Step 4: upgrade firmware
Step 5: after Step 4, go to Step 2 and check if the mode is still preserved (if preserved
then PASS else FAIL)
5. SNMP (supported from Grantley platform)
Step 1: Please go to add a new user and enable SNMP function.
Step 2: check if the user added and SNMP function enabled
Step 3: go to Web-UI to check "SNMP" to be preserved