Table 28: Performance Monitoring Configuration Commands (Available in both Auto Mode and Manual
Mode) (continued)
Command
set 24-minute a tca-low b
set 24-minute a tca-high c
set 24-minute a tca-low-en d
set 24minute a tca-high-en d
set 24-minute a tca-low b tca-high c
set 24-minute a tca-low-en d tca-high-en d
Table 29 on page 84
describes the TCA-high and TCA-low values.
Description
Sets the following 24-hour performance monitors:
TCA-low threshold.
TCA-high threshold.
TCA-low enable or disable option.
TCA-high enable or disable option.
NOTE:
Some of these options can be combined in a
single command.
a: Enter one of these values:osc-a-tx-power,
osc-a-rx-power, osc-a-estimated-fiber-loss,
voa-a-attenuation, edfa-ab-input-power,
edfa-ab-output-power, edfa-ab-signal-output-power,
edfa-ab-pump0-current, edfa-ab-pump1-current,
edfa-ab-pump0-temperature,
edfa-ab-pump1-temperature, osc-b-tx-power,
osc-b-rx-power, osc-b-estimated-fiber-loss,
voa-b-attenuation, edfa-ba-input-power,
edfa-ba-output-power, edfa-ba-signal-output-power,
edfa-ba-pump0-current, edfa-ba-pump1-current,
edfa-ba-pump0-temperature,
edfa-ba-pump1-temperature
b: TCA-low threshold value.
c: TCA-high threshold value.
d: enable or disable
NOTE:
You can set your high and low TCA values
provided they do not exceed the values in
Table 29 on page 84
(TCA default values).