FRU Panel
The field-replaceable unit (FRU) panel of the optical ILA contains the fan modules and power supplies for
the optical ILA.
Figure 3 on page 19
Figure 3: Optical ILA FRU Panel
1
Grounding points
—
2
ESD point
—
The cooling system in an optical ILA consists of three 12.4-W fan modules. These fan modules can be
hot-swapped—you do not need to power off the optical ILA or disrupt the functioning of the optical ILA
to replace a fan module. The optical ILA has two 150-W power supplies, either AC or DC depending on
your configuration. The power supplies need to be both AC or both DC. Only one power supply is required
to power the device, while the second power supply provides redundancy.
Optical ILA Hardware Component Overview
Table 3 on page 19
describes the hardware components of the optical ILA.
Table 3: Optical ILA Hardware Components
Component
Spare Model Number
Chassis
PTX-ILA-M-AC
PTX-ILA-M-DC
PTX-ILA-M-CHAS
Fan module
FAN-ILA-S
Power supplies
JPSU-150-AC-AFO
JPSU-150-DC-AFO
shows the FRU panel on the optical ILA.
3
Fan modules
—
4
Power supplies
—
Description
"Optical ILA Chassis Description" on page 22
"Optical ILA Cooling System Description" on page 29
"Optical ILA AC Power Supply Description" on
page 31
"Optical ILA DC Power Supply Description" on
page 32
19