Table 32: Alarm Descriptions (continued)
Alarm Name
edfaEbaOOG
edfaEbaPump0EOL
edfaEbaPump1EO
edfaEbaPump0Temperature
edfaEbaPump1Temperature
edfaEbaInputLOS
Description
EDFA E-ba is out of gain. This alarm
is triggered if the difference between
the gain setting and the actual
achieved gain is more than 0.5 dB.
E-ba is the B to A direction (for
example, west to east).
EDFA E-ba pump 0 has reached its
end of life.
E-ba is the B to A direction (for
example, west to east).
EDFA E-ba pump 1 has reached its
end of life.
E-ba is the B to A direction (for
example, west to east).
EDFA E-ba pump 0 temperature
alarm. If the pump temperature is
below 20° C or greater than 30° C, an
alarm is triggered.
E-ba is the B to A direction (for
example, west to east).
EDFA E-ba pump 1 temperature
alarm. If the pump temperature is
below 20° C or greater than 30° C, an
alarm is triggered.
E-ba is the B to A direction (for
example, west to east).
EDFA E-ba input power alarm. If the
input power is within 1.5 dB of the
threshold for the minimum input
power, an alarm is triggered.
E-ba is the B to A direction (for
example, west to east).
Corrective Action
Wait for the optical ILA control loops
to self-adjust.
Reset the optical ILA, or return the
device by using an RMA.
Reset the optical ILA, or return the
device by using an RMA.
When pump temperature is between
20° and 30° C, the alarm is cleared.
When pump temperature is between
20° and 30° C, the alarm is cleared.
When the input power is at least
1.5 dB greater than the threshold
value, the alarm is cleared.
109