10.1 Factory Settings Of The Outputs For Dn15 / Dn20 / Dn25 - E+E Elektronik EE741 Series User Manual

Inline flow sensor for compressed air and gases
Hide thumbs Also See for EE741 Series:
Table of Contents

Advertisement

10.1 Factory Settings of the Outputs for DN15 / DN20 / DN25

Standard volume flow [Nm³/h]
Standard volume flow [Nm³/min]
Standard volume flow [l/min]
Standard volume flow [l/s]
Standard volume flow [SCFM]
Mass flow [kg/h]
Mass flow [kg/min]
Standard flow [Nm/s]
Standard flow [SCFM]
Temperature [°C]
Temperature [°F]
Pulse output:
Pulse duration:
Pulse value:
Measured value averaging:
26
Analogue output
Pipe
from
diameter
DN15
0
DN20
0
130
DN25
0
200
DN15
0
1.25
DN20
0
2.15
DN25
0
3.3
DN15
0
1250
DN20
0
2150
DN25
0
3300
DN15
0
DN20
0
DN25
0
DN15
0
DN20
0
DN25
0
117
DN15
0
DN20
0
165
DN25
0
255
DN15
0
1.6
DN20
0
2.8
DN25
0
4.3
DN15
0
120
DN20
0
120
DN25
0
120
DN15
0
23600
DN20
0
23600
DN25
0
23600
DN15
-20
DN20
-20
DN25
-20
DN15
-4
140
DN20
-4
140
DN25
-4
140
0.1 s
1 m³
10
User Manual EE741 Inline Flow Sensor for Compressed Air and Gases
Switch output
hysteresis mode
to
SP
HY
75
50
5
90
9
150
15
0.83
0.08
1.5
0.15
2.5
0.25
833
83
1500
150
2500
250
20
14
1.4
35
25
2.5
55
40
4
44
30
3
76
53
5.3
88
8.8
97
65
6.5
115
11.5
195
19.5
1
0.1
2
0.2
3.2
0.32
80
8
80
8
80
8
15000
1500
15000
1500
15000
1500
60
24
0.5
60
24
0.5
60
24
0.5
75
1
75
1
75
1
Minimum flow
shutdown
SP
HY
0.15
0.07
0.25
0.12
0.35
0.17
0.15
0.07
0.25
0.12
0.35
0.17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ee741-n50Ee741

Table of Contents