This user manual serves for ensuring proper handling and optimal functioning of the device. The
user manual shall be read before commissioning the equipment and it shall be provided to all
staff involved in transport, installation, operation, maintenance and repair. The user manual may
not be used for the purposes of competition without the written consent of E+E Elektronik® and
may not be forwarded to third parties. Copies may be made for internal purposes. All information,
technical data and diagrams included in these instructions are based on the information available
at the time of writing.
Disclaimer
The manufacturer or his authorized agent can be only be held liable in case of willful or gross
negligence. In any case, the scope of liability is limited to the corresponding amount of the order
issued to the manufacturer. The manufacturer assumes no liability for damages incurred due to
failure to comply with the applicable regulations, operating instructions or the specified operating
conditions. Consequential damages are excluded from the liability.
1.1

Explanation of Symbols

This symbol indicates safety information.
It is essential that all safety information is strictly observed. Failure to comply with this information
can lead to personal injuries or damage to property. E+E Elektronik® assumes no liability if this
happens.
This symbol indicates instructions.
The instructions shall be observed in order to reach optimal performance of the device.
1.2

Safety Instructions

1.2.1

Intended Use

The inline flow sensor (device) is dedicated to the measurement of compressed air and non-
corrosive gases in pipelines. Please consult the manufacturer before employing the device in wet
or dirty gases.
The inline flow sensor consists of a sensing unit and a gauge mounting block. The sensing unit
may only be installed in the appropriate E+E gauge mounting block. It is not permissible to use
the sensing unit without a gauge mounting block.
Due to the design the flow sensor is appropriate for operation in pressurized systems up to 16
bar (232 psi) (PN16).
It is not allowed to operate the EE741 in explosion hazard areas. The surrounding area of the
sensing unit must not be an explosion-hazard area. When used with flammable gases, explosive
atmospheres in the pipeline must be avoided at all times.
Installation, electrical connection, maintenance and commissioning may only be performed by
qualified, trained and authorized staff.
Use other than described in the present operation manual may represent a security risk for
people and the entire measuring chain and is therefore not permitted. The manufacturer may not
be made liable for injuries damages caused by inappropriate or non-intended use or installation.
To prevent safety risks and damages, and assure full functionality of the device, the user
shall strictly observe the start-up, inspection and maintenance steps described in this manual.
Furthermore, the device may not be manipulated in any other way than described in these
operating instructions, and may not be exposed to any excessive mechanical stress.
The flow sensor may be operated only under the ambient conditions as defined in the technical
data sheet. Use under other ambient conditions may lead to device malfunctions.