  • Page 1 Operation Manual EE211 HEATED HUMIDITY / TEMPERATURE SENSOR BA_EE211_e // V1.3 // technical data are subject to change...
  • Page 2 E+E Elektronik Ges.m.b.H. doesn‘t accept warranty and liability claims neither upon this publication nor in case of improper treatment of the described products. The document may contain technical inaccuracies and typographical errors. The content will be revised on a regular basis. These changes will be implemented in later versions. The described products can be improved and changed at any time without prior notice.
  • Page 3: Table Of Contents

    CONTENT General ..............................4 Explanation of Symbols ..........................4 1.1.1 General Safety Instructions ..........................4 Environmental Aspects ..........................4 1.2.1 Mounting and Start-up ............................5 Scope of Supply ..........................5 Accessories ..............................5 Spare Parts ..............................5 Product Description ..........................5 Operation Principle ............................5 Dimensions in mm (inch) ..........................6 Connection Diagram ............................6 LED Indication ...............................7 Display ................................7...
  • Page 4: General

    Intended use The EE211 is intended for the measurement of relative humidity (RH) and temperature (T) in environment with continuous high humidity. The use of the EE211 other than described in this manual is not recommended. The manufacturer cannot be held responsible for damages as a result of incorrect handling, installation and maintenance of the device.
  • Page 5: Mounting And Start-Up

    Based on the measured values humidity and temperature, the EE211 calculates the dew point temperature Td whereas the separate, interchange- able T-probe measures the ambient temperature. Ultimately, out of Td and T, the device calculates the relative humidity RH as well as several other parameters like absolute humidity, mixing ratio, wet bulb temperature or enthalpy.
  • Page 6: Dimensions In Mm (Inch)

    (approx. 5 °C = 9 °F) means max. 76 % RH humidity at the sensors and enables following benefits: • The sensing head of EE211 stays dry even under condensing conditions, which prevents dust and dirt from sticking to the sensor and leads to outstanding long-term stability.
  • Page 7: Led Indication

    • Insert the M20 cable gland included in the scope of supply into the corresponding opening of the EE211 basis unit and fix it tight with the nut. Alternatively, it is possible to install a 1/2” conduit fitting (not included in the scope of supply).
  • Page 8: Setup

    Setup The EE211 is ready to use and does not require any configuration by the user. The factory setup of EE211 corresponds to the type number ordered. For ordering guide please see data sheet at www.eplu- se.com/ee211. If needed, the user can change the factory setup by using the USB configuration adapter (cod HA011066) and the EE-PCS, Product Configuration Software.
  • Page 9: Address Switch

    [°C], [°F] 30036 0x23 absolute humidity [g/m³], [g/ft³] 30038 0x25 mixing ratio [g/kg], [gr/lb] 30040 0x27 specific enthalpy [kJ/kg], [BTU/lb] 30042 0x29 frost point temperature [°C], [°F] Tab. 3 Float (read register) Operating manual EE211 Heated humidity and temperature sensor...
  • Page 10 Register number starts from 1 Register address starts from 0 The choice of measurement units (metric or non-metric) must be done in the ordering guide, see EE211 data sheet. Switching from metric to non-metric or vice versa by using the EE-PCS is not possible.
  • Page 11: Reading Example

    Reading Example Example of MODBUS RTU command for reading the temperature (float value) T = 26.652524 °C from the register 0x19: Device EE211; slave ID 239 [EF in Hex] Reference document, chapter 6.3: www.modbus.org/docs/Modbus_Application_Protocol_V1_1b.pdf Request [Hex]: EF 03 00 19 00 02 EB 7B...
  • Page 12: Maintenance

    Omniport 30 can be optionally supplied with an accredited calibration certificate. See E+E calibration brochure at www.eplusecal.com. • For multiple point calibration or 2-point adjustment for RH and T, the EE211 as a whole (both probes) shall be placed in a climate chamber.
  • Page 13: Individual Calibration / Adjustment Of The T Probe

    In case of individual adjustment, the adjustment data is stored in the T probe, the factory setup of the EE211 basis unit is not altered. Consequently, the T probe can be readjusted or replaced at any time without the need of readjusting the EE211 basis unit.
  • Page 14: Technical Data

    The accuracy was calculated in accordance with EA-4/02 and with regard to GUM (Guide to the Expression of Uncertainty in Measurement). 2) USA & Canada: class 2 supply required, max. supply voltage 30V Operating manual EE211 Heated humidity and temperature sensor...
  • Page 15 Operating manual EE211 Heated humidity and temperature sensor...
  • Page 16 HEADQUARTERS SUBSIDIARIES E+E Elektronik Ges.m.b.H. E+E Elektronik Germany E+E Elektronik France E+E Elektronik Korea Langwiesen 7 info@epluse.de info@epluse.fr Tel: +82 31 732 6050 A-4209 Engerwitzdorf Tel: +33 4 74 72 35 82 info@epluse.co.kr Office Bad Homburg Austria Tel: +49 6172 13881-0...

Table of Contents