Figure 4-15: Spherical
P113/P123 = Spherical
P114/P124 = (1.0 / Diameter of tank)
P115/P125 = Plotted non-linear profile of tank
P116/P126 = Full volume of ideal spherical tank
Figure 4-16: Conical
P113/P123 = Conical
P114/P124 = (1.0 / Maximum level)
P115/P125 = Plotted non-linear profile of tank
P116/P126 = Full volume of ideal conical tank
Note
The non-linear profile (NLP) is plotted automatically when editing P113/P123 manually or
when using the Application (App) Wizard, except for the Conical NLP. Menu: SETUP →
[CONTROLLER] → APPLICATION → App Wizard
P115/P125 is plotted with a simple cone if P113/P123 is set to Conical manually.