(6) Use the standard power supply cables for Europe (such as H05RN-F or H07RN-F which conform to CENELEC (HAR) rating specifications) or use the cables
based on IEC standard. (60245 IEC57, 60245 IEC66)
Loose wiring may cause the terminal to overheat or result in unit malfunction. A fire hazard may also occur.
Therefore, ensure that all wiring is tightly connected.
WARNING
When connecting each power wire to the terminal, follow the instructions on "How to connect wiring to the terminal" and fasten the wire
securely with the terminal screw.
For the shield part of the shielded cable, twist the end out, crimp it with a round terminal, and connect
it to the functional earthing screw.
After crimping it with a round terminal, wrap it with insulating tape so there are no spaces and adjust it
so the shield part does not touch any live parts.
Be sure that the shield part of the shielded cable does not touch the terminal
CAUTION
block or any live parts.Failure to do so may lead to electric shock or fire.
How to connect wiring to the terminal
For stranded wires
(1) Cut the wire end with cutting pliers, then strip the insulation to expose the stranded wire
about 10 mm and tightly twist the wire ends.
(2) Using a Phillips head screwdriver, remove the terminal screw(s) on the terminal board.
(3) Using a ring connector fastener or pliers, securely clamp each stripped wire end with a
ring pressure terminal.
(4) Put the removed terminal screw through the ring pressure terminal and then replace and
tighten the terminal screw using a screwdriver.
Crimp the round terminal
Shield part
Stranded wire
Special washer
Wire
1-10-8
Wrap it well with insulating tape
so there are no spaces.
Ring pressure
terminal
Screw
Ring pressure
Screw and Special
terminal
washer
Ring pressure
terminal
Terminal board