Panasonic S-160PE1R5B Technical Data & Service Manual page 27

Table of Contents

Advertisement

(B) Outdoor Units
U-200PZH2R8
MODEL No.
Source
Controller P.C.B. Ass'y
Control circuit fuse
Compressor
Model....number
Source
Nominal output
Compressor oil
Coil resistance
(Ambient temperature 25°C)
Safety control
Overload relay models
Operation temperature
Crank case heater
Refrigerant amount at shipment
High pressure switch
Set pressure
Fan
Number...diameter
Air circulation
Fan speeds (Max.)
Fan motor
Model No.
Source
No. of pole
Nominal output
Safety device
Operating temperature
Run capacitor
Heat exchanger
Coil
Rows...fin pitch
Face area
W
cc
Open °C
Close °C
W
kg
OFF
MPa
ON
MPa
mm
m
/ h
3
W
Open °C
Close °C
VAC, µF
mm
m
2
1-1-1-2-8
U-200PZH2R8
400 - 415V 3-Phase 50Hz
ACXA73C49250
30A
9VD550XAA21
460V DC MOTOR
4,800
1,900
U-V 0.735  U-W 0.715  V-W 0.715
Discharge temperature control
230V-32W
R32-5.2
4.15
+0
-0.2
3.05±0.2
2...ø540
160
NFD-81FW-D8120-6, NFD-81FW-D8120-7
DC280V
8
120
Aluminium plate fin / Copper tube
3...17FPI
1.367
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents