(B) Outdoor Units
U-160PZH2R8
MODEL No.
Source
Controller P.C.B. Ass'y
Control circuit fuse
Compressor
Model....number
Source
Nominal output
Compressor oil
Coil resistance
(Ambient temperature 25°C)
Safety control
Overload relay models
Operation temperature
Crank case heater
Refrigerant amount at shipment
High pressure switch
Set pressure
Fan
Number...diameter
Air circulation
Fan speeds (Max.)
Fan motor
Model No.
Source
No. of pole
Nominal output
Safety device
Operating temperature
Run capacitor
Heat exchanger
Coil
Rows...fin pitch
Face area
W
cc
Open °C
Close °C
W
kg
OFF
MPa
ON
MPa
mm
m
/ h
3
W
Open °C
Close °C
VAC, µF
mm
m
2
1-1-1-2-6
U-160PZH2R8
400 - 415V   3-Phase 50Hz
ACXA73C49270
30A
9VD550XAA21
460V DC MOTOR
3,800
1,900
U-V 0.735  U-W 
0.715
Discharge temperature control
230V-32W
R32-3.2
4.15
+0
-0.2
3.05±0.2
2...ø540
164
NFD-81FW-D8120-6, NFD-81FW-D8120-7
DC280V
8
120
Aluminium plate fin / Copper tube
2...18FPI
1.367
1
V-W 
0.715