Husqvarna Automower Technical Manual page 75

Hide thumbs Also See for Automower:
Table of Contents

Advertisement

4. Autocheck, Service program
Manual test: Loop
3012-568
In order to test the loop signals and to receive useful
values the test must be performed where there is a
boundary wire and a charging station installed. It must
be a test surface of at least a few square metres
around the charging station. It also requires the mower
to be connected to the installation.
The values for the different loop signals are shown in
the Loop signals box. These values are an indication of
how well the loop system is functioning. The loop
signals can be measured through the front or the rear
loop sensor. Select which sensor is to be tested by
checking either Front loop sensor or Rear loop sensor.
Point to a value or a heading and the relative field and
loop are shown in the picture at the bottom of the
screen.
Below the column with values it is stated whether the
mower is standing with the front loop sensor Inside
loop or Outside loop.
Automower from
75