Husqvarna Automower Technical Manual page 47

Hide thumbs Also See for Automower:
Table of Contents

Advertisement

If the guide wire runs on the left, seen in the
mower's direction of entry, the guide wire must
be routed at least 2 m from the front edge of the
charging plate. In this instance, Automower will
find it difficult to find the low loop signal
strengths, i.e. if a high Corridor width value is
used. There is then a risk that the mower will not
find the right strength on the loop signal and can
not follow the guide wire.
If Automower does not find the right strength on
the loop signal when it leaves the charging
station, it will start to mow immediately instead.
Tip! If Automower finds it difficult to follow the
guide wire out from the charging station, the
guide wire should, if possible, be routed further
out from the front edge of the charging plate.
Should this not be possible, reduce the reversing
length or set a lower Corridor width value.
If the guide wire is to be used for the Follow loop in function:
When the guide wire is only used for the Follow
loop in function it is sufficient for the guide wire to
be routed 70cm straight out from the front edge of
the plate.
When the Automower follows the guide wire in
towards the charging station it ignores the F-field.
Should the mower, when it follows the guide wire,
collide with an obstacle, it changes direction and
leaves the guide wire.
The standard boundary wire, 535 13 17-01, should be
used for the guide wire.
The guide wire should be connected to the boundary
wire with the help of an original connector,
535 13 37-01. See the picture opposite.
3. Installation
2 m
3012-710
3012-643
Automower from
47

Advertisement

Table of Contents
loading

Table of Contents