2. Special menu functions
STOP button override (5-6-4)
When STOP button override is actuated the
Automower can be started and stopped with the help of
the number 0 instead of the STOP button. This function
is suitable when the display is difficult to read on a
working mower, for example, when charging or running
in Live data mode.
The function is switched off automatically when the
mower is switched off and on using the main switch.
Table 7: Factory settings
Function
Drive past wire
Reversing distance from charging station
Exit angles
Follow loop out
Boundary delay
Guide delay
Boundary corridor
Guide corridor
Timer
Time lock
Stop protection
Settings lock
Square mode cutting (EXP-position)
Sounds Keypad
Sounds Operation
Garden shape
40
Automower from
Value (min – max)
27cm (15 – 50cm)
60cm, random ± 20cm (15 – 300cm)
90° – 270° (45° – 315°)
No area activated
11 minutes
7 minutes
6
6
No limitation
30 days
Deactivated
Deactivated
50% (1% – 100%)
LOW
OFF
Normal