2. Special menu functions

Fault messages (5-1-3)

This part menu contains the following information:
By date
a list containing 100 of the latest registered fault
messages sorted by date with the last fault to occur
first. Each message is shown with the date and time.
Reset fault
a function to delete all saved fault messages. To
reset: Place the cursor on Reset fault and press YES.
Now press YES when asked Reset fault counter?.
The message Clearing fault log is shown for a few
seconds.

Software (5-1-4)

This sub-menu contains information about the
software (mower program's) version, the control box
version and date of issue. The version consists of
both the edition and the program type. The edition
number is stated as a combination of four numbers,
for example, Ver 02.32. The program type states
which type of mower program Automower is
programmed with. B states the control box version.

Battery history (5-1-5)

This sub-menu contains information about the
battery's capacity. In order to check the capacity of
the battery, the battery needs to be fully discharged.
For more information, see Battery check on page 20.
The four most recent battery checks are saved in
Battery history.
Switch between the four display modes by using
Arrow up or Arrow down.
32
Automower from
Operating data
Trip Op. counters
Fault messages
Software
Battery history
5-1-3
Operating data
Trip Op. counters
Fault messages
Software
Battery history
5-1-4
Operating data
Trip Op. counters
Fault messages
Software
Battery history
5-1-5
By date
Reset fault
AMG2
Ver: xx.xx B:
Date:
Time:
Date:
Capacity:
Chargings OK:
Batt. Temp: