It is also possible to switch the square cutting function
off completely. However, this should only be done in
exceptional cases. To switch off square cutting: Select
the function OFF and press YES. Place the cursor on
OFF and press YES again.
Reset square cutting is used to reset the time counter
for square mode cutting. An Automower
uninterrupted (mowing + charging) for about 13 – 14
hours before it can start square mode cutting. This
function is used, for example, if you wish to prevent
square mode cutting when the mower is moved from a
well-mown area to an unmown area. Select the
function and press YES when the cursor is on Yes to
reset.

New startup sequence (5-6-2)

This function can be used when a second-hand
Automower
is sold. The new owner will then be asked
®
the start-up questions about language, date, and time
when the main switch is turned ON for the first time. In
addition, all settings on the Automower
restored to their original values, see Table 3: Factory
settings, page 42.
To select a new start-up sequence: Place the cursor on
New start-up sequence and press YES. Now press
YES when asked Select new startup?.

Calibrate tilt sensor (5-6-3)

To calibrate, i.e. reset the tilt sensor: Place the
Automower
®
on a horizontal surface. Place the cursor
on Calibrate tilt sensor and press YES. Now press YES
when asked Calibrate tilt sensor?.

STOP button override (5-6-4)

When STOP button override is actuated the
Automower
can be started and stopped with the help
®
of the number 0 instead of the STOP button. This
function is suitable when the display is difficult to read
on a working mower, for example, when charging or
running in Live data mode.
The function is switched off automatically when the
mower is switched off and on using the main switch.
Table 3: Factory settings
Function
Drive past wire
Reversing distance from charging station
Exit angles
Follow loop out
42 - English
2. SPECIAL MENU FUNCTIONS
®
must run
®
will be
220 AC, 230 ACX, Solar Hybrid, 260 ACX
Value (min – max)
27cm (15 – 50cm), 11" (6" - 20")
60cm, random ± 20cm (15 – 300cm)
24", random ± 8" (6" - 120")
90° – 270° (45° – 315°)
No area activated