Operating Data (5-1-1) - Husqvarna Automower 210 C Technical Manual

Hide thumbs Also See for Automower 210 C:
Table of Contents

Advertisement

2. SPECIAL MENU FUNCTIONS

Operating data (5-1-1)

This part menu contains information about:
Key data
Search times
Key data
Total running (h) =
Total running is defined as the accumulated time
in hours that the wheel motors have run. This
means the time when the Automower
without mowing is also included in the running
time. The time stated here is the time stated in
the main menu.
Run time/fault (h) =
an average time of how many hours the
Automower
has run for each fault message
®
displayed. Run time/fault is the total running time
divided by the number of occurring faults.
Docking efficiency (%) =
a measurement of on how many occasions when
the Automower
has reached the N-field this has
®
resulted in a successful docking.
Docking efficiency should be as high as possible.
Normally the value for docking efficiency is about
90 % or higher.
Searching (%) =
a measurement of how much of the total running
time that the Automower
charging station.
The value for searching varies depending on the
size of the working area and the design of the
installation. You should aim for the lowest possible
searching value. Depending on the installation, it
is normal for the mower to search between
10 – 20 %.
Efficiency (%) =
a measurement of how much of the total operating
time that the Automower
Efficiency is the mowing time divided by the
charging time+running time.
Time/charge (min) =
an average time for how long each charging
period has taken.
runs
®
®
has searched after the
®
has mown the lawn.
Operating data
Trip Op. counters
Fault messages
Software
Battery history
5-1-1
Key data
Search times
Key data
Search times
Total running
Run time/fault
Docking efficency
Searching
Efficiency
Time/charge
English - 33

Advertisement

Table of Contents
loading

Table of Contents