Live Data (5-3); Blade Motor (5-3-1); Wheel Motors (5-3-2); Battery (5-3-3) - Husqvarna Automower 210 C Technical Manual

Hide thumbs Also See for Automower 210 C:
Table of Contents

Advertisement

Mower position = the part of the angle sensor that
states Mower normal pos. or Mower reversed.
The tilt sensor can be calibrated if necessary via
the function Tools- Special settings - Calibrate tilt
sensor (shortcut 5-6-3).
Ultrasonic distance = indicates the mower's
distance to the closest obstacle. A correct value is
between 40-300 cm (16"-120") and changes when
the mover moves forward or backward in relation
to the obstacle. The test is best completed
outdoors on the grass.

2.7.3 Live data (5-3)

This function can be used to study an Automower
operation. Using Live data you receive relevant data
for respective component groups or function.
Select a group and start the Automower
values (data) are shown on the display when the
mower is working. See 2.7.2 Test (5-2), page 35 for
more information about the different values. Press
Arrow back to exit.

Blade motor (5-3-1)

Current, average current, speed and voltage are
shown.

Wheel motors (5-3-2)

Power L, power R, pulse difference and speed are
shown.

Battery (5-3-3)

Voltage, charge, current and battery temperature are
shown.

Loop (5-3-4)

Values for the loop signals, quality and restart are
shown.

Sensors (5-3-5)

Positions for the collision sensors, lift sensor and tilt
sensor are shown.

Customized (5-3-6)

Customized is a function to determine which four
values are to be shown on the display when real time
data is started. However, the function does not need to
be use other than on the direct request of
Husqvarna AB.
40 - English
2. SPECIAL MENU FUNCTIONS
®
. A group of
®
in
Operating history
Test
Live data
Demo mode
Loop detection
Special settings
Blade motor
Wheel motors
Battery
Loop
Sensors
Customized