If after the ball replacement the problem
is still unsolved, replace the complete
check valve p/n 118830017/0 (F)
Pay attention, if the check valve doesn't
fit perfectly well, please replace the end
part (G) with the old one. To make this
operation it's enough unscrew the part
above (H).
4.8 Vacuum pump
The vacuum pump is developed to cre-
ate a vacuum in the tank to facilitate at
service and repairs affecting the hydrau-
lic system.
Connection
1. Remove the engine covers. See
"2.2.1".
2. Unscrew the cap for tank vent valve
A.
3. Install the suction hose B from the
vacuum pump on the tank vent valve.
4. Connect the positive and negative
cable C on the machine battery D.
5. Adjust the vacuum using knob E. The
vacuum must be between 0.2 -0.4
bar.
6. Switch on pump F.
WORKSHOP MANUAL
TITAN
Chapter
4 - Hydraulic system
EDITION
Page
2018