6.2.8 The starter motor can be
activated when the engine
is running
Does the hour counter function?
Check connector A, clean if
necessary
6.2.9 The sand spreader does not
function
Sand spreader socket rear:
Connect a voltmeter to 31 (ground)
and 54 (orange).
Then to 31(ground) and 58 (black).
Activate the switch between its posi-
tions.
Does the voltmeter show 12 V at both
meterings?
Front connection C. Connect a volt-
meter to ground and C1 (black).
Then to ground and C2 (orange).
Activate the switch between its posi-
tions.
Does the voltmeter show 12 V at both
meterings?
WORKSHOP MANUAL
TITAN
No
No
Chapter
6 - Electrical system
Replace safety relay
Yes
Repair the sand spreader
Yes
Check connector C,
Yes
clean if necessary
Replace the sand
No
spreader switch on the
control panel
EDITION
Page
2018
102