Troubleshooting - Raven AccuBoom Installation Manual

Miller condor g-series
Table of Contents

Advertisement

CHAPTER
5
The AccuBoom CAN control node (P/N 063-0172-316) features several green light-emitting diodes (LEDs)
which may be used to diagnose issues within the AccuBoom system.
Note:
If the LEDs are not displayed as outlined in the figure below, check the CAN connections and the
control cable connections on the node. If the issue persists, contact your local Raven dealer for
additional technical support.
Note:
All boom switches must remain in the On position while AccuBoom control is in operation.
AccuBoom CAN Control Node LEDs
FIGURE 1.
Manual No. 016-1001-076
T roubleshooting
C h a p t e r 5
Logic Power - Lit when +12 V current is
supplied to the node.
HC (High Current) Power - Lit when High
Current Power is supplied to the node.
Micro 1 Hz - Flashes once every second
during processor activity.
CAN Rx - Flashes to indicate CAN messages
are being received by the node.
CAN Tx - Flashes to indicate CAN messages
are being transmitted from the node.
Diag (Diagnostics) 1/2 - Currently not used
with the AccuBoom™ system.