Troubleshooting

The following are a few general tips for troubleshooting the product control
system. Refer to the Envizio Pro and Envizio Pro II Installation and Operation
manual for detailed troubleshooting information.
Issue
CANbus cannot
read Node(s)
Both
Off
Enabled
Possible Cause Solution
• CANbus ends
not terminated
• Corroded pins
in CANbus
connections
• Moisture in
connection
• Connectors
not seated
properly
Left/Right
Enabled
Glide Series AutoBoom Calibration
• Make sure that both ends of the CANbus
system are properly terminated. Refer to
the Envizio Pro and Envizio Pro II
Installation and Operation manual for
more information.
• Check CANbus cable connectors for any
highly corroded pins.
• Ensure dielectric grease has been
applied to all cable connections exposed
to weather and field conditions.
• Check CANbus cable connectors for any
corroded pins.
• Ensure dielectric grease has been
applied to all cable connections exposed
to weather and field conditions.
• Check that all CANbus cable connectors
are inserted fully (until the locking tab is
engaged).
• Be sure to remove any moisture in
connections which were not properly
seated. Check for corroded pins and
apply dielectric grease when
reconnecting CANbus cables.