AudioCodes MediaPack Series Hardware Installation Manual page 48

High-density analog media gateway
Hide thumbs Also See for MediaPack Series:
Table of Contents

Advertisement

CHAPTER 6    Hardware Maintenance
every 6 months. In air- purified (conditioned) rooms, air filter replacement can be done
annually. It's the user's responsibility to determine the cleanness level and the air filter
replacement frequency.
The air filter is hot-swappable.
➢ To replace the air filter:
1.
On the front panel, remove the Fan Tray cover, by loosening the four Philips-head, spring-
loaded captive screws located in each corner of the cover and then gently pulling the cover
away from the chassis:
2.
Remove the air filter cover, located on the inside of the Fan Tray cover, by removing the
two flat-head, spring-loaded captive screws located on either side of the air filter cover,
using a flathead screwdriver:
Figure 6-6:
3.
Pull out the exposed air filter from the enclosure of the air filter cover and dispose of it:
The device's components may be damaged due to a dirty or blocked air filter.
Replace the air filter only with an air filter purchased from AudioCodes.
Before removing the air filter, make sure that you have the replacement air filter on
hand so that you can replace it immediately.
Figure 6-5:
Removing Fan Tray Cover on Front Panel
Removing Air Filter Cover from Fan Tray Cover