(F5) 
 
Voltage Parameters   
Below are the automatically measured voltage parameters for the oscilloscope and their 
definitions:   
Vpp:  P eak‐to‐peak voltage. 
Vmax: Maximum voltage. 
Vmin: Minimum voltage. 
Vmid: Medium voltage.   
Vamp: The voltage amplitude from waveform top to bottom.   
Vtop: The voltage value from waveform top to GND (Ground). 
Vbase: The voltage value from waveform base to GND (Ground).   
Over‐shoot: The ratio of (Vmax – Vtop) to voltage amplitude (Vamp). 
Pre‐shoot: The ratio of (Vmin – Vbase) to voltage amplitude (Vamp). 
Average: The average signal amplitude within 1 cycle.   
Vrms: Root‐mean‐square value (effective value). 
 
Time Parameters   
Rise Time: The time of waveform amplitude rising from 10% to 90%. 
Fall Time: The time of waveform amplitude falling from 90% to 10%.   
+Width: The width of positive pulse at 50% amplitude.   
‐Width: The width of negative pulse at 50% amplitude.   
Delay (rising edge): The delay time between rising edges. Delay (falling edge): the delay 
time between falling edges.   
+Duty: The ratio of positive pulse width to cycle.   
‐Duty: The ratio of negative pulse width to cycle.   
 
9. Set the Cursor Measurement 
Users can press the  CURSOR button to enable the cursor measurement function of the 
oscilloscope, where the location of the CURSOR button can be found in the figure below. 
 
 
 
 
function menu 
CH1 
Select CH1 as source 
CH2 
Select CH2 as source 
 
Select different voltage parameters 
 
Select different time parameters 
 
Press to display all the measurement 
parameters of the input source. Or, press 
to turn off parameter display. 