Figure 4 shows a Card Access System using an Ethernet network with RS-485
subnetworks. The Card Access Controllers connecting to a Master Node's
RS-485 subnetwork are Slave Nodes to the Master Node. Each RS-485
subnetwork can have up to 63 controllers connected to it; you can still have more
than 63 Master Nodes connected to the Ethernet network.
Ethernet Network
Figure 4.
If you connect to the Ethernet TCP/IP network with the TX3 Configurator, you
can configure any of the nodes in the system. If you connect directly to a
controller using USB, a modem, or a COM port, you will only be able to
configure devices that are on the same RS-485 subnetwork as that device.
Note:
TX3-CX Card Access System Installation and Operation Manual
10
LT-980
Copyright 2017
Card Access Controller
(Master Node)
Card Reader A
Card Reader B
RS-485 Subnetwork
Card Access Controller
(Master Node)
Card Reader A
Card Reader B
RS-485 Subnetwork
Card Access System using both Ethernet and RS-485
networks
There can only be one Master Node on an RS-485 subnetwork. That
is, you cannot connect one RS-485 subnetwork to another RS-485
subnetwork. However, if you want to connect to a Touch Screen
panel remotely over the Internet (for instance, to configure Touch
Card Access Controller
(Slave Node)
Card Reader A
Card Reader B
Card Access Controller
(Slave Node)
Card Reader A
Card Reader B