Method 33:
Move at "Slower Speed" in the negative direction
Until the index pulse is reached
This method is intended for position measuring systems that feature only one index
mark (single index).
Figure 8.62: Homing method 33
Method 34:
Move at "Slower Speed" in the positive direction
Until the index pulse is reached
This method is intended for position measuring systems that feature only one index
mark (single index).
Figure 8.63: Homing method 34
Method 37:
With this method, the current position becomes the zero position.
Figure 8.64: Homing method 37