Method -1:
Move at "Faster Speed" in the negative direction
Move up to the hard stop until "End stop current" is reached
On reaching this, decelerate, stop, and move at "Slower Speed" in the posi-
tive direction until the next index pulse is reached
"End stop current" defines the current limit when the drive moves to the end limit.
"Time" defines the time during which the set "End stop current" is active.
Figure 8.51: Homing method -1
"End stop current" is given in peak, and not effective amperes!
Method 1:
Move at "Faster Speed" in the negative direction
Move until the negative hard switch outputs a rising edge
On reaching this, decelerate, stop, and move at "Slower Speed" in the posi-
tive direction until the next index pulse
Figure 8.52: Homing method 1