For Hp Internal Use Only; Scsi/Console/Lan Pca Access Port Error Codes; Ta Command Tests And Power-On Selftests - HP 3000 Series Handbook

Pa-risc computer systems
Hide thumbs Also See for 3000 Series:
Table of Contents

Advertisement

For HP Internal Use Only
SCSI;Console;LAN PCA Access Port Error Codes.
This is a list of the error codes that can occur when the
TA
command is used on
SCSI/Console/LAN PCA, P /N A1703-60003.
Table 5-39. TA Command Tests and Power-on Selftests
Test
Test Description
Nmnber
1
OCT ART tests ( Never runs because oct art is always busy)
2
Flash ROM test
3
Firmware ROM test
4
IODC ROM test
5
EEPROM test
6
Local port ENQ/ ACK test
7
Remote port ENQ/ ACK test
8
LAN loopback test
If a test fails, the following message is displayed:
Additional Failure Information
TTTTSSSS HHHHHHHH HHHHHHHH
TTTT
is the first two bytes of the self test number in ASCII hex.
SSSS
is the second two bytes of the self test number in ASCII hex.
HHHHHHHH
is for internal use only.
The selftest failure test codes are shown in Table 5-40.