4.18.6 Engineer Restore of Faults
If 'YES', an Engineer code must be used to reset the EURO control panel after the following
faults: ATE telecom fail, Modem fail, ATE single path fail, Telecom line fail, Battery disconnect,
Batt charge, Battery load, Excessive charge, Battery critical and Device fail.
4.18.7 Anti-Code Restore
If 'YES', the EURO control panel will display an Anti-Code, to which can be used to generate a
special reset code (usually from the ARC) to reset the EURO control panel.
NOTE: that if Anti-Code is selected, this will coincide with the options that have been selected
previously. For example, if 'Engineer Restore Intruder' is selected, and Anti-Code is selected,
then an anti-code will be produced on intruder activation.
Engineer Reset Options Programming
1. Press or to scroll to 'SITE OPTIONS'. Press .
2. 'Engineer Restore Intruder' will be displayed. Use or to
enable/disable each option and press . Repeat for all functions.
The Engineer menu will be displayed once all functions have
finished.
4.19 Review Logs
The control panel has two Event Logs, which are time and date stamped. The first log which is a
panel log, records all events that occur on the EURO control panel, i.e. Users entering their codes to
set or unset areas, alarm events, failures to set etc.
The second log which is an access log, only records access control events.
4.19.1 Panel Log
The Panel log records all events that occur on the EURO control panel, i.e. Users entering their
codes to set or unset areas, alarm events, failures to set etc. Pressing will give more
information of the display (for example, shows which user unset the EURO control panel).
4.19.2 Access Log
The Access log records all events for Access Control events.
With each log, use the key to move from one event to the previous event. The key will
move from one event to the next event that occurred.
To view additional details, press the key. If no other information is available, the display will
move to the next log entry. Pressing the key will return to the main screen for that entry.
NOTE: For all Fault Codes refer to Appendix F (page 51).
Review Logs Programming
1. Press or to scroll to 'REVIEW LOGS'. Press .
2. 'Panel log' will be displayed. Press to display the panel log.
3. The time, date and event will be displayed. Use or to
scroll through the event log. If more information is required, for
example, if 'Alarm on Input' is displayed, press to show more
information (e.g. the input that activated). Press to exit the
Panel log.
4. 'Access log' will be displayed. Press to display the access log
and repeat the operations mentioned above. Press to exit to
the Engineer menu.
EURO 46, 162 & 280 Programming Manual
Page: 28
ENGINEER RESTORE
OPTIONS?
Eng Restore Int
No
REVIEW LOGS?
Panel log?
28/04 12:47:49
Engineer Access
Access log?
[0]
Need help?
Do you have a question about the Castle EURO 46 Series and is the answer not in the manual?