4.15.6 Output Module Outputs
If any Output Expander Modules (EURO-OEM8R8T, or EURO-OEM16R+PSU) are connected to the
EURO control panel, they must be addressed in this function. All output programming is done
also here. A maximum of 1 output expander can be connected to the EURO control panel. Refer
to the installation manual (RINS1529) for more information.
Change Output Programming
1. Press or to scroll to 'CHANGE OUTPUTS'. Press .
2. 'Endstation Outputs' will be displayed. Press to program any
endstation outputs, Press or to scroll through the outputs
or the select the shortcut number. Press for the next output.
'ATE Pin 1 ' will be displayed. Press to program any ATE
ouptuts if a communication loom is connected to the EURO system
or press for the next function. Press or to scroll
through the outputs or the select the shortcut number.
3. 'ZEM Outputs' will be displayed. Press to program any ZEM
outputs (on the EURO-ZEM8+ or EURO-ZEM8+PSU if connected),
or press for the next function.
4. 'Wireless Bells'' will be displayed. Press to program any
wireless output types or press for the next function.
5. 'Output Module Outputs'' will be displayed. Press to address an
output module (EURO-OEM8R8T or EURO-OEM16R+PSU if
connected) or press for the next function.
6. 'Keypad Outputs' will be displayed. Press to program any
outputs on any additional keypads connected or press for the
next function.
7. 'Reader Outputs' will be displayed. Press to program any
outputs on any readers connected or press to return to the
Engineer menu for the next function.
4.15.7 Follow Input [0035]
The Follow Input (output type 0035) is active when a specific input number has been activated
and it allows the following options to be programmed:
- Follow Type ([0] Follow, [1] Timed, [2] Latched, [3] Code Reset);
- Follow What ([0] Input, [1] Shunt List, [2] Ward, [3] Area);
- Follow When ([0] When Set, [1] When Unset, [2] Always);
NOTE: The Follow Input will not function correctly if assigned to ATE pins.
Change Output Programming: Follow Input
1. Press or to scroll to 'CHANGE OUTPUTS'. Press .
2. 'Endstation Outputs' will be displayed. Press and enter '0035'
for Follow Input.
3. 'Follow Type' will be displayed, Press or to scroll through
the options and press . NOTE: If 'Timed' is selected the time
that output will stay on has to be entered.
4. 'Follow What' will be displayed, Press or to scroll through
the options and press .
5. 'Follow When' will be displayed, Press or to scroll through
the options and press .
6. 'Input To Follow', 'Shunt To Follow, 'Ward To Follow' or 'Area To
Follow' will be displayed depending on which option was selected in
'Follow What'. Press .
EURO 46, 162 & 280 Programming Manual
Page: 25
CHANGE OUTPUTS?
Endstation
Outputs?
BELL O/P
[0014]
Siren Any
ATE Pin 1 [0001]
Fire
ZEM Outputs?
Wireless Bells?
Output Module
Outputs?
CHANGE OUTPUTS?
Endstation
Outputs?
Output 1
[0035]
Follow Input
Follow Type
Latched
Follow What?
Input
[2]
[0]
Need help?
Do you have a question about the Castle EURO 46 Series and is the answer not in the manual?