4.15.6 Output Module Outputs
If any Output Expander Modules (EURO-OEM8R8T, or EURO-OEM16R+PSU) are connected to the
EURO control panel, they must be addressed in this function. All output programming is done
also here. A maximum of 1 output expander can be connected to the EURO control panel. Refer
to the installation manual (RINS1529) for more information.
Change Output Programming
1. Press or to scroll to 'CHANGE OUTPUTS'. Press .
2. 'Endstation Outputs' will be displayed. Press to program any
endstation outputs, Press  or  to scroll through the outputs
or the select the shortcut number. Press  for the next output. 
'ATE Pin 1 ' will be displayed. Press to program any ATE
ouptuts if a communication loom is connected to the EURO system
or press  for the next function. Press  or  to scroll
through the outputs or the select the shortcut number.
3. 'ZEM Outputs' will be displayed. Press to program any ZEM
outputs (on the EURO-ZEM8+ or EURO-ZEM8+PSU if connected),
or press  for the next function.
4. 'Wireless Bells'' will be displayed. Press to program any
wireless output types or press  for the next function.
5. 'Output Module Outputs'' will be displayed. Press to address an
output module (EURO-OEM8R8T or EURO-OEM16R+PSU if
connected) or press  for the next function.
6. 'Keypad Outputs' will be displayed. Press to program any
outputs on any additional keypads connected or press  for the
next function.
7. 'Reader Outputs' will be displayed. Press to program any
outputs on any readers connected or press  to return to the
Engineer menu for the next function.
4.15.7 Follow Input [0035]
The Follow Input (output type 0035) is active when a specific input number has been activated
and it allows the following options to be programmed:
- Follow Type ([0] Follow, [1] Timed, [2] Latched, [3] Code Reset);
- Follow What ([0] Input, [1] Shunt List, [2] Ward, [3] Area);
- Follow When ([0] When Set, [1] When Unset, [2] Always);
NOTE: The Follow Input will not function correctly if assigned to ATE pins.
Change Output Programming: Follow Input
1. Press or to scroll to 'CHANGE OUTPUTS'. Press .
2. 'Endstation Outputs' will be displayed. Press and enter '0035'
for Follow Input. 
3. 'Follow Type' will be displayed, Press  or  to scroll through
the options and press . NOTE: If 'Timed' is selected the time
that output will stay on has to be entered.
4. 'Follow What' will be displayed, Press  or  to scroll through
the options and press .
5. 'Follow When' will be displayed, Press  or  to scroll through
the options and press .
6. 'Input To Follow', 'Shunt To Follow, 'Ward To Follow' or 'Area To
Follow' will be displayed depending on which option was selected in
'Follow What'. Press .
EURO 46, 162 & 280 Programming Manual
Page: 25
CHANGE OUTPUTS?
Endstation
Outputs?
BELL O/P
[0014]
Siren Any
ATE Pin 1 [0001]
Fire
ZEM Outputs?
Wireless Bells?
Output Module
Outputs?
CHANGE OUTPUTS?
Endstation
Outputs?
Output 1
[0035]
Follow Input
Follow Type
Latched
Follow What?
Input
[2]