Emerson Rosemount 5600 Series Reference Manual page 106

Level transmitter non-contacting radar with hart protocol
Hide thumbs Also See for Rosemount 5600 Series:
Table of Contents

Advertisement

Reference Manual
00809-0100-4024, Rev CA
Table A-9. Cone Antenna with Integrated Flushing Connection Ordering Information
Code
Antenna size
94S
4 in. (DN100) nozzles
96S
6 in. (DN150) nozzles
98S
8 in. (DN200) nozzles
Code
Tank seal
P
PTFE
Q
Quartz
Code
O-ring material
V
Viton
K
Kalrez 6375
E
EPDM
B
Buna-N
Code
Process connection
XX
Special process connection
Code
Stainless steel flange welded to antenna
CL
4 in. ANSI Class 150
DL
6 in. ANSI Class 150
FL
8 in. ANSI Class 150
JL
DN100 PN16
KL
DN150 PN16
LL
DN200 PN16
Code
Options
Q8
Material Traceability Certification per EN 10204 3.1.B
Typical model number: Selected code from
Table A-10. Transmitter Options (multiple selections allowed)
Code
Options
Material Trraceability Certification
Q8
Material Traceability Certification per EN 10204 3.1B
Calibration Data Certification
Q4
Calibration Data Certificate
Software Configuration
C1
Custom Software Configuration (CDS required with order)
Specifications and Reference Data
Antenna
Note
material
SST 316L
Consult factory
SST 316L
Consult factory
SST 316L
Consult factory
Note
Consult factory
Note
Max 101 psig at 392°F (7 bar at 200°C)
Max 145 psig at 392°F (10 bar at 200°C)
Max 145 psig at 392°F (10 bar at 200°C)
Max 72 psig at 392°F (5 bar at 200°C)
Max 87 psig at 392°F (6 bar at 200°C)
Max 87 psig at 392°F (6 bar at 200°C)
Table A-4 on page 102
94S P K KL
Specifications and Reference Data
March 2020
106