Mechanical Installation
March 2020
7. Rotate the antenna so the groove on the antenna feeder is directed 90° to the tank wall.
Figure 2-39. Groove on Antenna Feeder
Groove
8. Tighten the finger nut and the lock nut.
9. Mount the adapter nut on top of the antenna feeder.
Tighten the adapter nut firmly.
10. Insert the wave guide tube into the upper wave guide.
Figure 2-40. Inserting the Wave Guide Tube into the Upper Wave Guide
Upper wave guide
Wave guide tube
11. Carefully mount the Transmitter Head onto the adapter and tighten the upper wave guide nut by
hand. Make sure that the guide pins on the adapter fits into the holes on the upper wave guide.
Figure 2-41. Mounting the Transmitter
Upper wave guide nut
44
Antenna feeder
Adapter
Reference Manual
00809-0100-4024, Rev CA
Mechanical Installation