Panasonic YP-060PF Operating Instructions Manual page 64

Igbt controlled plasma arc cutting power source
Table of Contents

Advertisement

13 Troubleshooting (continue)
Error
The
number
content
E08
Current
abnormity
E11
Air
abnormity
E13
Electrode
circuit abnormity
E17
422 Suspension
(422 communication
abnormity)
E40
Replacement of the
electrode
E41
Abnormity of input
air
exceeding
recommended
range
Note:
After trying the countermeasures but failed, please contact with the distributor.
abnormal
Causes and · countermeasures
detection
Failure may happen.
· please contact distributor
pressure
Air pressure lower than 0.28mpa
·It's OK to use when the air pressure is within the recommended range.
· Please confirm whether or not 1.5kwor high compressor is used.
short
Short circuit happens between cutting tip and electrode
· please replace cutting tip and electrode with new ones
· Please remove spatter attached the surface of the electrode and inside of the
nozzle.
·Please use specialized hand tool in accessory of the cutting torch to fasten
electrode and cutting tip correctly.
The abnormal content and countermeasures: Suspension and connection of the
robot.
Please cut off power switch and then restart.
When the cutting torch monitoring function is enabled, one of the set monitoring
number of times or duration of the cutting torch reaches the set value.
· Please turn off power source and then replace electrode and cutting tip with
new ones.
·turn on power source again; set the submenu "the cutting torch monitoring
warning setting (P06)" again.
When "the cutting torch monitoring warning setting (P06)" on submenu is "0",
the cutting torch monitoring LED blinks, and then cutting can start;When "the
cutting torch monitoring warning setting (P06)" is "1", digital display window
shows E40. The cutting does not function.
Air pressure exceeds the recommended range.
pressure
· Please adjust air pressure within the recommended range.
the
· please confirm the settings of submenu "the cutting torch cable length
selection (P10)" "the cutting torch selection (P11)" and whether or not the
cutting torch length matches the rated specification of the cutting torch.
Submenu "out-of-recommended range air pressure warning setting (P09)" is
under the setting of "air after cutting enable (0)", cutting is enabled, under the
setting of "air after cutting disable (1)" cutting is disenabled.