Panasonic YP-060PF Operating Instructions Manual page 34

Igbt controlled plasma arc cutting power source
Table of Contents

Advertisement

8 Settings and Operations
(continue)
(3) When one of number of arc ignition times and
actual cutting time reaches the set value, after
cutting operation finishes, by using 【the cutting
torch monitoring warning setting 「p06」 】 on the
submenu, operating status are as follows:
· When「P06」is「0」
「the cutting torch monitoring」LED blinks. After
that, cutting can be executed.
· When「P06」is「1」
When digital display window displays 「E40」,
there is no output.
(4) After installation of new electrode and cutting
tip, please execute the required reset operation
as (1) on 【 the cutting torch monitoring
selection 】of submenu.
8.6.2 The confirmation method for
monitoring number of times and
duration of the cutting torch
●The confirmation method for setting number of
times and duration
Select 【the cutting torch monitoring number of
times 「p04」 】 or 【the cutting torch monitoring
time setting 「p05」 】 of submenu. If pressing
the DECIDE button to enter menu item, 【the
cutting torch monitoring number of times
「p04」 】 of submenu shows the set number of
times. "【the cutting torch monitoring time
setting 「P05」 】 of submenu shows the set
cutting time.
blink
blink
30

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents