8 Settings and Operations
(continue)
8.6.1 Operation method
(1) Enter 【the cutting torch monitoring selection
「p02」 】 on direct setting or submenu, turn the
dial to display 「 reset rst」, press the DECIDE
button. At this moment, the cutting torch
monitoring function enter reset status.
·For setting in "direct setting"
·For setting in "submenu"
The monitoring function displaying LED for
cutting torch
·"(off)"--- goes off
·"(on)"--- is normally lit
(2) Enter 【the cutting torch monitoring selection
「p02」 】 of direct setting or submenu again, turn
the dial and select 「(on) 」, press the DECIDE
button.
·For setting in "direct setting"
blink
·For setting in "submenu"
29
blink