8 Settings and Operations
(continue)
(3) The display circularly shows in the sequence
of material, thickness, manual / automatic
selection, cutting current, the distance between
cutting tip - base metal and recommended cutting
speed. On the status, please press selection
button, the confirmation on the condition of
cutting navigation finishes, enter setting mode of
submenu. If pressing again, machine enters the
stand-by status.
Material
Thickness
Manual /
automatic
selection
Cutting current
Cutting tip —
base metal
distance
Recommended
cutting speed

8.5 The submenu

·The submenu is a mode executing a fine
adjustment or setting on the cutting machine
power source according to parameter unit.
·Please modify set values according to the need.
For parameters details, please refer to 【8.5.3the
detailed content】.
·There are two methods setting the items in the
submenu, direct setting and setting via submenu.
·The direct setting on submenu contents can be
realized by using self-hold selection (P07), the
cutting torch monitoring selection (P02) and
gouging selection (P01).
·The detailed operation sequences are as follows:
8.5.1 The direct setting
(1) On stand-by status, if the selected button is
pressed 1~3 times, "self-hold", corresponding
LED of "the cutting torch monitoring" and
"gouging" blinks, executing the corresponding
setting.
· Direct setting for "self-hold selection (P01)"
(2) Rotate the dial to modify the set value of
parameters, press the DECIDE button.
After setting, return to the stand-by status. When
the setting is "(on)", the function display LED of
the corresponding item is lit.
· Direct setting for "self-lock selection (P01)"
25