A. Technical appendix
General
Vibration and shock
Vibration
Shock
1)
The double−solenoid valve (Ident. code J) consists of two valve sub−bases.
2)
2
1 g = 9.81 m/s
Tab. A/1:
General technical specifications
A−4
Tested as per DIN/IEC 68/EN 60068 part 2−6,
severity class 2: 10...60 Hz: 0.35 mm
Tested as per DIN/IEC 68/EN 60068 part 2−27,
severity class 2: 30 g / 11 ms
Caution:
If possible, operate the CPV−SC valve terminal with non−
lubricated auxiliary pilot air (connections 12/14). Other
wise observe the instructions in the section Preparing
the compressed air" in chapter 3.
With CPV−SC valve terminals with internally branched
auxiliary pilot air, the above mentioned remark also
applies to the supply air (connection 1).
2
60...150 Hz: 2 g
2)
Festo P.BE−CPVSC−EN en 0301a