2. Fitting
1
Additional fasten
ing holes in the
left−hand end
plate
Disconnecting
2−6
Valve
L1
locations
4
8
33.2 mm (+ 0.1 mm)
12
16
Tab. 2/1:
Fastening possibilities for fitting onto a wall
3. Fasten the CPV−SC valve terminal to the wall with four M3
screws of sufficient length (tightening torque 0.6 Nm
(+ 0.2 Nm)).
4. If necessary, use the fastening holes in the left−hand end
plate for additional fastening of the CPV−SC valve termi
nal. In order to do this, use an M3 socket head screw with
at least 45 mm shaft length.
Proceed as follows:
1. Prevent a hanging CPV−SC valve terminal from falling
down before you loosen it from the fastening surface.
2. Loosen the fastening screws in the end plates.
3. Remove the CPV−SC valve terminal from the fastening
surface.
L2
1
L2
114 mm (± 0.5 mm)
156 mm (+ 0.9/− 0.5 mm)
198 mm (+ 1.3/− 0.5 mm)
240 mm (+ 1.7/− 0.5 mm)
Festo P.BE−CPVSC−EN en 0301a