4. Commissioning
Actuating the manual override with automatic reset
(non−locking)
Tab. 4/5:
Non−locking manual override
4−10
Please note
Use a screwdriver for actuating the non−locking manual
·
override.
Actuate the manual override at 7 bar with max. 25 N.
·
You will then avoid malfunctioning or damage to the
manual override.
Use a screwdriver to carefully
press down the plunger of the
manual override as far as
possible.
Hold the plunger of the manual
override pressed down.
Release the plunger. The
spring resets the plunger of
the manual override to the
basic position.
Reaction of the valve
The valve
moves to the switching
position
remains in the switch
position
moves back to the basic
position (not with 5/2−way
double−solenoid valve,
Ident. code J)
Festo P.BE−CPVSC−EN en 0301a