3. Installation
Setting the lubricator
Checking the setting
3−6
With the machine running (typical operating status) 0.2 to
max. 1 drop/min. or 0.5 to 5 drops/1000 l air.
The procedure described below can be used for checking the
setting of the lubricator.
Proceed as follows:
Check the service units in respect of condensate and
·
lubricator setting twice a week.
1. Ascertain the cylinder which is furthest from the
lubricator.
2. Ascertain the valve terminal which controls this cylinder.
3. Remove the silencer, if fitted, from connection 3/5.
4. Hold a piece of white cardboard 10 cm in front of the
exhaust port.
5. Let the system run for a short period.
There must only be a slight yellow colouring on the
cardboard. If oil drops out, this is an indication that
too much oil has been used.
A further indication of excessive lubrication is the colouring
or status of the exhaust silencer. A distinctly yellow colouring
of the filter element or drops of oil on the silencer indicate
that the lubricator setting is too high.