2.4 Connecting the Emulator System

How to connect the emulator system is described hereafter.
Figure 2.5 Connecting the emulator system

(1) Connecting the USB Interface Cable

Connect the USB interface cable (included) to the USB interface connector (J2) and the USB port
of the host machine (see Figure 2.5).

(2) Connecting the Power Cable

Connect the power supply for the emulator to the power connector (J1). The specification of the
power supply for the emulator is listed in Table 2.6.
Table 2.6 Specification of power supply of the emulator
Power supply voltage
Figures 2.6 and 2.7 show the specifications of the power connector and an applicable plug,
respectively.
Figure 2.6 Specification of the power connector
Note on Connecting the Power Supply of the Emulator:
To emulator power supply
Connect the power cable to connector J1.
LED1
POWER
SAFE
LED2
LED3
POWER
CLOCK
RESET
RUN
LED6
COMPACT EMULATOR
DC 5.0 V ±5%, 2 A
Electrode (+)
• Be careful about the polarity of the power supply. Connecting to the wrong electrode
could destroy internal circuits.
• The power cable included in this product package is colored red (+) and black (-).
• Do not apply a voltage exceeding the specified voltage of the product (5.0 V ±5%),
because it may cause burn injuries and the failure of internal circuits.
To host machine
Connect the USB interface cable to connector J2.
SW1
J2
J1
MADE
Electrode (-)
Figure 2.7 Specification of an applicable plug
CAUTION
( 22 / 56 )
ø1.7 mm (Inside diameter)
ø4.75 mm