2.2 Starting Up the Emulator

The procedure for starting up the emulator is shown in Figure 2.3. For details, refer to each section
hereafter. And, when the emulator does not start up normally, refer to "Chapter 5. Troubleshooting"
(page 43).
Connect the power supply for the emulator.
Figure 2.3 Procedure for starting up the emulator
Set the MCU power supply source
selection jumper (JP1).
Set the function selection switches
(SW1, SW2 and SW3).
Connect the USB interface cable.
Connect the target system.
Turn on the emulator.
Check the LEDs of the emulator.
Start up the emulator debugger.
Specify the operating environment.
Debug the program
using the emulator debugger.
Set the switch according to the connection to the
target system.
- When not connected: INT
- When connected: EXT
Set the switch according to the usage.
- SW1: P87/XCIN
- SW2: P86/OPEN
- SW3: XOUT/OPEN
Connect the USB interface cable to the USB interface
connector (J2) of the emulator and the USB port of
the host machine.
Connect the power supply to the power connector
(J1). Emulator power should be 5.0 V ±5%, 2 A.
Connect the target system to the emulator when
necessary.
Recheck the connection, and turn on the emulator.
When the target system is connected, turn on the
target system too. Turn them on as simultaneously
as possible.
Check that the system status LEDs and "POWER"
and "CLOCK" of the target status LEDs light. When
the target system is not connected "POWER" does
not light.
Start up emulator debugger PD30M.
In the INIT dialog box of emulator debugger PD30M,
specify the following, and press the OK button.
- MCU file: M306K9.mcu
Emulator debugger PD30M offers various debugging
functions. For details on PD30M, refer to the online
manual of PD30M.
( 19 / 56 )