Connecting To A 144-Pin 0.5Mm Pitch Foot Pattern - Renesas R0E3308B0EPB00 User Manual

Table of Contents

Advertisement

R0E3308B0EPB00 User's Manual

2.9.4 Connecting to a 144-pin 0.5mm pitch Foot Pattern

Figure 2.11 shows how to connect the emulation probe to a 144-pin 0.5mm pitch foot pattern on the user system with the M3T-
FLX-144NSD (not included), and here following is its procedure. For details on the M3T-FLX-144NSD, refer to its user's
manual.
(1) Attach the NQPACK144SD included with the M3T-FLX-144NSD to the user system.
(2) Attach the YQPACK144SD included with the M3T-FLX-144NSD to the NQPACK144SD.
(3) Insert the YQ-GUIDE's included with the YQPACK144SD to the YQPACK144SD.
(4) Attach the M3T-FLX-144NSD to the YQPACK144SD.
(5) Attach the R0E3308B0EPB00 to the M3T-FLX-144SD.
These corners are not round.
*: These four items are available in one package.
Figure 2.11 Connecting to a 144-pin 0.5mm pitch foot pattern
Notes on Connecting the User System:
• Take care not to attach the converter board in a wrong direction. It may cause a fatal damage to the emulator.
• The small connectors of the R0E3308B0EPB00 and M3T-FLX-144NSD are guaranteed for only 50
insertion/removal iterations.
• NQPACK, YQPACK, YQ-GUIDE, HQPACK are products of Tokyo Eletech Corporation.
R20UT0210EJ0200 Rev.2.00
Sep 16, 2010
M3T-FLX160-EPB
R0E3308B0EPB00
CN2 side
(5)
M3T-FLX-144NSD
(4)
YQ-GUIDE (x4)
*
YQPACK144SD
(3)
NQPACK144SD
(2)
144-pin 0.5mm pitch
(144P6Q) foot pattern
(1)
No. 1 pin
CAUTION
(not included)
On-board evalution
HQPACK144SD
(not included)
FLASH MCU etc.
User system
2. Setup