(2) If an Error is Detected in the Self-check

Table 5.6 lists how to remedy the troubles if the target status LED display is abnormal in the self-
check.
When an error is detected, shut off the emulator and the target system and follow the steps in the Table
5.6. Then, reactivate the power of the emulator and the target system.
Table 5.6 Error display in the self-check and how to remedy it
LED display
: Blinking
: OFF
POWER
CLOCK
RESET
RUN
The emulator system does not work properly.
- Check that power is supplied to the emulator.
- The emulator may be damaged. Contact your local distributor.
A clock is not supplied to the emulator.
- Check that the oscillator circuit board (OSC-3) is attached.
The emulator system does not work properly.
- The emulator may be damaged. Contact your local distributor.
Notes on the Self-check:
• Be sure to disconnect the target system before executing the self-check.
• If the self-check does not result normally, the emulator may be damaged. Then,
contact your local distributor.
• Use the preinstalled oscillator circuit board OSC-3 (16 MHz) to execute the self-
check.
Problem & remedy
CAUTION
( 49 / 56 )