Using The Emulator Without The Target System; Using The Emulator With The Target System - Renesas M306K9T2-CPE User Manual

Compact emulator with real-time trace functions for m306k9
Table of Contents

Advertisement

Chapter 3. Changing the Settings

3.1 Using the Emulator without the Target System

How to use the emulator without the target system is shown below.
(1) Set the "MCU power supply source selection jumper" to INT side (see page 20).

3.2 Using the Emulator with the Target System

How to use the emulator with the target system is shown below.
(1) Set the "MCU power supply source selection jumper" to EXT side (see page 20).
(2) Connect the target system (see page 23).
(3) Connect the power supply for the emulator (see page 25).
The target MCU operates with 3.3 V of power supply voltage supplied from the emulator.
When using the emulator with the target system, set the "MCU power supply source selection
jumper" to EXT side.
Connect the emulator to the target system via a pitch converter board (not included).
As the emulator cannot supply power to the target system, provide the target system with a
separate power supply from that of the emulator.
( 30 / 56 )