Installation; Delivery Inspection And Unpacking; Inspection; Unpacking - Cornelius REMCOR OLYMPUS POST-MIX Service Manual

Table of Contents

Advertisement

CAUTION
service this unit. ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL
CODES.
D
I
ELIVERY
NSPECTION AND

Inspection

Upon delivery inspect the unit for damage or irregularities and immediately report problems to the deliver-
ing carrier and file a claim with that carrier.

Unpacking

Remove shipping tape and other packing material.
Unpack the loose parts and make sure all items are present.
Drain Hose - P/N 50119
Clamps - P/N 70339
Decals - P/N varies with dispenser
I
R
NSTALLATION
EQUIREMENTS

Requirements Summary

Weight:....................................... counter must be level and able to support at least 100 kg (220 lbs.)
Environment: ............................. indoor installation only
Temperature: ............................. 4° to 43° C (40 to 110° F) ambient temperature
Clearance: ................................. 46 cm (18-in) above 15 cm (6-in) for side panel vents
CO
:........................................... 5.2 bar (75 psi) at dispenser
2
Syrup: ........................................ 4.1 bar (60 psi)
Water: ........................................ 4.5 bar recommended (65 psi), (min. 3.5 to max. 5.2 bar (50-75 psi))
Electrical: ................................... nominal 230 VAC, 50 or 60 Hz
................................................... 180 VAC min. operating voltage
................................................... 255 VAC max. operating voltage
................................................... nominal 115 VAC, 60 Hz
................................................... 90 VAC min. operating voltage
................................................... 130 VAC max. operating voltage

Electrical Requirements

Before connecting electrical power to the dispenser refer to nameplate to verify power requirements.
DANGER —
breaker) must be installed in the electrical circuit.
WARNING
green grounding screw provided inside the electrical contractor box.
© 2002, IMI Cornelius Inc.

INSTALLATION

— Only trained and certified electrical, plumbing and refrigeration technicians should
U
NPACKING
LOOSE PARTS:
Name
To avoid possible serious injury or death the ELCB (earth leakage circuit
— To avoid possible electrical shock the unit must be electrically grounded using the
Olympus Post-Mix Service Manual
Quantity
5 feet
2
1 set
- 5 -
Publication Number: 750300229